I/O - Properties - X142

2021-07-28 浏览次数:99
I/O - Properties - X142

You can configure the following operating modes for the individual channels of the X142 interface:


列表: Overview of operating modes

Operating mode of X142 I/Os
(8 channels)

Functionality

Use with technology objects (TOs)

Use via I/O area (without TO)

Isochronous mode

DI

Digital input

Input delay (1 µs/125 µs)

Hardware interrupt (optional)

Hardware interrupt at rising and/or falling edge

Hardware limit switch for positioning and synchronous axes

No OB restrictions

Optional

DQ

Digital output

Output cam

Cam track

No OB restrictions

Optional

Timer DI

Acquisition of the switching time of a digital input ** with up to two edges per application cycle (e.g. for use as measurement sensing input)

Measuring input (OB 91 required)

OB 91/OB 6x
required

Required

Timer DQ

Precisely timed output of a digital output ** with up to two edges per application cycle (e.g. for use as an output cam output)

Output cam (OB 91 required)

Cam track (OB 91 required)

OB 91/OB 6x
required

Required

Oversampling DI

Acquisition of 32 states of a digital input ** at equal intervals per application cycle

---

OB 91/OB 6x
required

Required

Oversampling DQ

Output of 32 states of a digital output ** at equal intervals per application cycle

---

OB 91/OB 6x
required

Required

Event/period duration measurement

Measurement of number of edges and period duration (e.g. for simple speed measurement with hole mask and light barrier)

---

OB 91/OB 6x
required

Required

Pulse width modulation PWM

Output of a configurable pulse-pause ratio with a configurable frequency

---

No OB restrictions

Optional